EAW Smaart 6 Operation Manual Analysis Modes and Display Types
37
Chapter 3: Analysis Modes and Display Types
Smaart 6 has two analysis modes: Real-time and Impulse Response (IR Analysis). These
run in separate windows.
Real-time mode processes incoming data continuously and offers four display types:
RTA, Spectrograph, Magnitude, and Phase. RTA and Spectrograph displays are
considered Spectrum measurements, where each data set displayed is based directly
upon FFT data from a single signal. The Magnitude and Phase displays show Frequency
Response data based on the transfer function of two signals. Smaart 6 starts up with a
single-pane view with the RTA display type.
The Spectrum and Freq. Resp. buttons configure the real-time window with the two
displays corresponding to each of their respective measurement types:
Click the Spectrum button to display a two-pane window with display types
set to Spectrograph (top) and RTA (bottom).
Click the Freq. Resp. button to display a two-pane window with display types
set to Phase (top) and Magnitude (bottom).
Even if the single-pane View is selected, clicking the Spectrum or Freq. Resp. buttons
changes to a two-pane View. Of course, any display type can be subsequently selected.
Figure 3-1 View and plot display after clicking the Spectrum button